HOME | C803-CFR | IN MEMORIAM | V. I. P. = V. I. P | SITE MAP | ALPHABETIC MAP | GLOBAL LAWS | ETHANOL | ATMOSPHERE | COPPER/PLASTIC | DISTILLATION | FEEDSTOCK$ | FERMENTATION | BOILER / REBOILER | HEAT EXCHANGER | GO SOLAR | TOOLS | ELECTRO | ENGINES | S.E.E.F.A | LINKS | REFERENCES | APPENDICES | DOWNLOADS | ETHANOL FUEL MANUAL | FACTS





Enter subhead content here
















  GPH Recovery At Indicated
Temperature Rise
Heating
Element
Wattage
60° 70° 80° 90°

100°

750 5.1 4.4 3.8 3.4 3.1
1,000 6.8 5.8 5.1 4.6 4.1
1,250 8.5 7.3 6.4 5.7 5.1
1,500 10.2 8.8 7.7 6.8 6.1
2,000 13.7 11.7 10.2 9.1 8.2
2,250 15.4 13.2 11.5 10.2 9.2
2,500 17.1 14.6 12.8 11.4 10.2
3,000 20.5 17.5 15.4 13.6 12.3
3,500 23.9 20.5 17.9 15.9 14.3
4,000 27.3 23.4 20.5 18.2 16.4
4,500 30.7 26.3 23.0 20.5 18.4
5,000 34.1 29.2 25.6 22.7 20.5
5,500 37.6 32.2 28.2 25.0 22.5
6,000 41.0 35.1 30.76 27.31 24.61  

  GPH Recovery At Indicated
Temperature Rise 
Input
Rating
Btuh
60° 70° 80° 90° 100 °
30,000 45.5 39.0 34.1 30.3 27.3
33,000 50.0 42.9 37.5 33.3 30.0
35,000 53.0 45.5 39.8 35.4 31.8
40,000 60.6 51.9 45.5 40.5 36.4
43,000 65.2 55.8 48.9 43.4 39.1
50,000 75.8 64.9 56.8 50.5 45.5
60,000 90.9 77.9 68.2 60.6 54.5
70,000 106.1 90.9 79.5 70.7 63.6
80,000 121.2 103.9 90.9 80.8 72.7
90,000 136.4 116.9 102.3 90.9

81.8

100,000 151.5 129.9 113.6 101.0

90.9


 

 
















Enter supporting content here