UTILITIES |
|||||
HOME | C803-CFR | IN MEMORIAM | V. I. P. = V. I. P | SITE MAP | ALPHABETIC MAP | GLOBAL LAWS | ETHANOL | ATMOSPHERE | COPPER/PLASTIC | DISTILLATION | FEEDSTOCK$ | FERMENTATION | BOILER / REBOILER | HEAT EXCHANGER | GO SOLAR | TOOLS | ELECTRO | ENGINES | S.E.E.F.A | LINKS | REFERENCES | APPENDICES | DOWNLOADS | ETHANOL FUEL MANUAL | FACTS
|
|||||
Enter subhead content here |
||||
-UTILITIES: COMMON
SPECIFICATIONS 1
Steam: 15-30 psig, 250-275°F; 150 psig, 366°F; 400 psig, 448°F; 600 psig, 488°F or with 100-150°F superheat.
2
Cooling water: Supply at 80-90°F from cooling tower, return at 115-125°F; return seawater at 110°F, return
tempered water or steam condensate above 125°F. 3
Cooling air supply at 85-95°F; temperature approach to process, 40°F. 4
Compressed air at 45, 150, 300, or 450 psig levels. 5
Instrument air at 45 psig, 0°F dewpoint. 6
Fuels: gas of 1000 Btu/SCF at 5-10 psig, or up to 25 psig for some types of burners; liquid at 6 million
Btu/barrel. 7
Heat transfer fluids: petroleum oils below 600°F, Dowtherms below 750°F, fused salts below 1100°F, direct
fire or electricity above 450°F. 8
Electricity: 1-100Hp, 220-550V; 200-2500Hp, 2300-4000V. |
||||
Enter supporting content here |
||||